Send Message
Qingdao Yilan Cable Co., Ltd. 86-- 18724796885 atwood.lee@hold-one.com
Power Soft Low Smoke Zero Halogen Cable Fire Resistant 1kV

Power Soft Low Smoke Zero Halogen Cable Fire Resistant 1kV

  • High Light

    1KV Low Smoke Zero Halogen Cable

    ,

    IEC Low Smoke Zero Halogen Cable

    ,

    Low Smoke Zero Halogen Power Cable

  • Rated Voltage
    0.6/1kV
  • Cores
    1,2,3,4,5
  • Standard
    IEC60502-1,IEC61034,IEC60754
  • Function
    Environmental Protection
  • Size
    1.5-600mm2
  • Color
    Customized
  • Package
    Free
  • Place of Origin
    China
  • Brand Name
    HOLD-ONE
  • Certification
    PCCC/ISOCE/KEMA
  • Minimum Order Quantity
    200m
  • Price
    USD 0.5-50/meter
  • Packaging Details
    Fumigation Wooden Drum
  • Delivery Time
    As per schedule
  • Supply Ability
    500km per month

Power Soft Low Smoke Zero Halogen Cable Fire Resistant 1kV

Low Smoke Zero Halogen Sheath Fire Resistant Power Soft Cable

 

Fire-Proof Wire and Cable Serial Products


1. Product Standard


Enterprise standard, this standard is equivalent to GB/T 19666-2005.


2. This product is suitable for use in all places using rated AC voltage 1-10 KV plastic insulated power cable, 450/750 V plastic insulated control cable, 450/750 V and below electrical equipment wire and cable , particularly high temperature , inflammable and fire. Proof for transmitting and distributing power , control , alarm and fire - control system and other circuits .


3. Property for Use


a. According to different product kinds , rated voltage can be divided into the following :
α. 0.6/1 - 8.7/10 KV β. 450/750 KV γ. 300/500 V δ. 300/300 V
b. Allowed work temperature of cable for a long period is divided into the following according to different kinds of products :
70ºC,90ºC,10
c. For short circuit(5s) , the allowed max.work temperature of conductor does not exceed 160ºC and 250ºC( for a-α).
d. Environmental temperature for laying cable should be not less than 0ºC.
f. Allowed min. Bend radius of cable should be according to different kinds of the following products : 6 times ,10 times,12 times and 15 times of cable overall diameter .
g. Cable combustion nature
α. Under flame temperature 750-800ºC combustion conditions , cable can normally operate not less than 90 min.
β. Measured cable current. Carrying capacity under "α" environment is not less than the current-carrying capacity value under work conditions of corresponding type and specifications of common cable.
h. Other electric nature and physical . Mechanic nature of cable are all higher than corresponding common cable.

 

Table 1
Type Name
NH-VV fire resistant PVC insulated,PVC sheath,copper power cable
NH-VV22 fire resistant PVC insulated,PVC sheath,steel belt armoured copper power cable
NH-YJV fire resistant XLPE insulated,PVC sheath,copper power cable
NH-YJV22 fire resistant XLPE insulated,PVC sheath,steel belt armoured copper power cable
NH-FF fluoroplastic isulated,fluoroplastic sheath copper power cable
WDZN-YY LSZH polyolefin insulated, polyolefin sheath copper power cable
WDZN-YY23 LSZH polyolefin insulated, polyolefin sheath steel belt armoured copper power cable
NH-YGG silicone rubber insulated, silicone rubber sheath copper power cable

 

Type Cores Rated voltage 0.6/1kv
Section(mm2)
NH-VV;NH-VV22;NH-FF;NH-YGG;NH-YJV;NH-YJV22;NH-WDZN-YY23 1~5 1.5~300;4~300
Table 3
Cable core diameterΦ Fluoroplastic sheath thickness
3-5 0.55
5.01-10 0.7
10.01-15 0.8
15.01-20 0.85
20.01-25 0.95
25.01-30 1.05
Property:
1,The ambient temperature for cable laying: above 0°C
2,Long-term maximum working temperature of PVC insulated conductor is not more than 70°C; NH-YJV conductor is not more than90°C;WDZN-YY conductor is not more than 90°C;NH-YGG conductor is not more than180°C;NH-FF conductor is not more than200°C.